6000W Pixel On-line EL Tester

6000W Pixel On-line EL Tester

A special instrument for rapid detection of solar module internal defects. shows the splits clearly according to the difference of luminous luminance of the cells in the solar modules.

Contact US >
  • Details
  • Introduction of equipment

    A special instrument for rapid detection of solar module internal defects. shows the splits clearly according to the difference of luminous luminance of the cells in the solar modules.

     

    Equipment characteristics

    1.Multi-camera multiple puzzles restore high-definition original pictures

    2.Automatic machine identification and manual aided judgment of defect types

    3.Oversized display window , high degree of reduction

    4.Can match with complete production Line

     

    Main technical or economic indicators

    Model

    SEL-V17.D5(EL6000-A)

    Applicable sample

    Crystal silicon solar module

    Effective test area

    2000mm×1100mm

    beat

    20Sec/Panel

    Suitable for

    Before Laminating/after Laminating

    resolution ratio

    6000W Pixel(500W*12)

    sensitivity

    ≥0 .3mm/pixel

    Test Time

    0s~60s  Continuously adjustable

    constant-current

    Programmable power supply

    Current Range

    0~13.4A  Continuously adjustable

    Voltage Range

    0~60V  Continuously adjustable

    Image storage

    Manual / automatic scanning bar code numbersNo. Name to be saved as the file name

    Motion control unit

    Using touch screen to communicate with PLC, real-time display of current status to monitor the process

    Control interface

    Chinese - English conversation interface , automatic control of constant current source on - off

    Screen

    Large screen 4K ultra clear display

    Software features

    Graphic display function, display fine features, single crystal automatic recognition,polycrystal auxiliary recognition, SQL database storage picture

    Defect type

    Crack, low efficiency cell, material defect, broken bus-bar, broken cell, black heart cell, etc.

    Voltage fluctuation allowed range

    AC single phase 220V±10%

    Frequency fluctuation allowed range

    50Hz/60Hz ±10%

    Power

    2 KW

    computer

    IPC

     

Hits:  UpdateTime:2019-05-03 18:20:22  【Printing】  【Close